3M Versaflo TR-800-PSK - Powered Air Purifying Respirator Assembly Painters Kit 7100150922
3M Versaflo TR-800-PSK - Powered Air Purifying Respirator Assembly Painters Kit 7100150922
3M Versaflo TR-800-PSK - Powered Air Purifying Respirator Assembly Painters Kit 7100150922
3M Versaflo TR-800-PSK - Powered Air Purifying Respirator Assembly Painters Kit 7100150922
3M Versaflo TR-800-PSK - Powered Air Purifying Respirator Assembly Painters Kit 7100150922
3M Versaflo TR-800-PSK - Powered Air Purifying Respirator Assembly Painters Kit 7100150922
3M Versaflo TR-800-PSK - Powered Air Purifying Respirator Assembly Painters Kit 7100150922
3M Versaflo TR-800-PSK - Powered Air Purifying Respirator Assembly Painters Kit 7100150922

3M Versaflo TR-800-PSK - Powered Air Purifying Respirator Assembly Painters Kit 7100150922

3M SKU: SS PSU TR-800-PSK
Regular price $5,102.73
/

Sold in multiples of 1 Each(s)

Shipping calculated at checkout.

Standard
Usually ships in 6 days

  • Secure payments

Complete intrinsically safe painter's PAPR kit

Integrated respiratory protection for professional paint operations

The 3M™ Versaflo™ TR-800-PSK Painters Kit combines an intrinsically safe TR-800 Series powered air purifying respirator with M-206 loose-fitting helmet headgear and an organic vapour, acid gas, and HE combination cartridge. The complete belt-mounted system is supplied with the battery, charger, breathing tube, covers, airflow indicator, and cleaning accessories needed to establish an approved workplace configuration.

  • NIOSH-approved PAPR system
  • Division 1 intrinsically safe
  • Three airflow settings
  • 1 complete kit per case

Designed for demanding paint and finishing work

TR-800-PSK brings the core components of a professional PAPR system together in one matched kit. Its loose-fitting headgear, selectable airflow, clear status indicators, and easy-clean components help support worker comfort and practical day-to-day maintenance in properly assessed paint-spray environments.

1

Intrinsically safe power unit

The TR-802N blower and mechanically attached TR-830N battery form the intrinsically safe power assembly for specified Division 1 and Zone hazardous locations.

2

Selectable airflow

Three airflow settings allow the wearer to select nominal loose-fitting flow rates of 190, 205, or 220 L/min.

3

Multi-mode alarms

Audible, vibratory, and visual alerts identify low airflow, low battery, or a system alarm so the wearer can leave the contaminated area.

4

Work-ready accessories

The easy-clean belt, breathing-tube cover, airflow indicator, filter cover, and cleaning kit support setup, inspection, and maintenance.

Kit contents

The catalog configuration includes the following matched 3M™ Versaflo™ components. Component substitutions can affect NIOSH approval and intrinsic-safety status.

TR-802NIntrinsically safe PAPR motor/blower
TR-830NStandard-capacity intrinsically safe battery
M-206Helmet and faceshield assembly
BT-20LLarge/medium breathing tube
TR-6510NOrganic vapour/acid gas/HE combination cartridge
TR-6500Filter/cartridge cover
TR-627Easy-clean belt
TR-642NSingle-station battery charger kit
TR-838Battery attachment tool
TR-971Airflow indicator
BT-922Disposable breathing-tube cover
TR-653Cleaning and storage kit

Typical applications

  • Professional paint-spray operations
  • Automotive refinishing and collision repair
  • Paint preparation and spray coating
  • Composite finishing and final finishing
  • Transportation manufacturing and maintenance

Worker-focused design

  • Loose-fitting helmet can accommodate limited facial hair and prescription eyewear
  • Automatic flow control compensates for filter loading, elevation, temperature, and battery state
  • Bright visual indicators communicate airflow, battery, and alarm status
  • Battery bumper and mechanical attachment help protect and secure the battery during use
  • Easy-clean belt uses non-porous, submersible material

Technical specifications

System type Belt-mounted powered air purifying respirator (PAPR)
Headgear type M-206 loose-fitting helmet and faceshield assembly
Included cartridge TR-6510N organic vapour/acid gas/high-efficiency particulate combination cartridge
Loose-fitting airflow settings Nominal 190, 205, and 220 L/min (6.7, 7.2, and 7.8 cfm)
Battery TR-830N standard-capacity rechargeable lithium-ion battery
Typical battery runtime Approximately 4 to 8 hours with a new battery and filter under stated 3M test conditions
Typical charging time Less than 4.5 hours; approximately 90% capacity in less than 3.5 hours
Alarms Audible, vibratory, and visual low-airflow, low-battery, and system alarms
Operating temperature -5°C to 55°C (23°F to 131°F)
Intrinsic-safety ambient range -20°C to 55°C (-4°F to 131°F)
Ingress protection IP54 during use; IP67 during cleaning when the TR-653 cleaning plugs are correctly installed
Approval NIOSH-approved PAPR system when assembled and used in an approved configuration
Hazardous-location classification Exia Division 1: IS Class I, II, III; Division 1, including Division 2; Groups C, D, E, F, G; T4. Additional Zone and mining classifications apply as marked by 3M and UL.
Case quantity 1 kit
3M catalogue number TR-800-PSK
3M product number 94248
3M stock number 7100150922
UPC 00076308942489
Country of origin United States

Runtime, airflow, protection, cartridge service life, and other performance depend on the complete approved configuration, selected airflow, filter loading, contaminants, concentrations, environmental conditions, maintenance, and work rate.

Inspection, charging, and storage

  • Charge the battery immediately and fully when the kit is received, following the TR-830 and TR-642N instructions.
  • Inspect the blower, battery, cartridge seal, breathing tube, headgear, belt, and airflow before every use.
  • Perform the required airflow check with the supplied TR-971 indicator before entering the contaminated area.
  • Never clean a filter or cartridge by knocking it or blowing out collected material.
  • Store the cleaned system and cartridge as directed by 3M, within the specified temperature and humidity limits.
  • Establish and document a cartridge change-out schedule based on the contaminants and workplace exposure assessment.

Critical respiratory and intrinsic-safety requirements

This system is for professional occupational use only. It must be selected, configured, inspected, maintained, and used within a compliant respiratory-protection program. In Canada, follow CSA Z94.4 and all requirements of the applicable jurisdiction. The wearer must read and understand every applicable 3M user instruction before use.

Do not use in oxygen-deficient atmospheres, where contaminant concentrations are unknown or immediately dangerous to life or health, or where concentrations exceed the maximum use concentration for the approved configuration. The filter-loading indicator measures particulate loading only and does not indicate remaining gas or vapour cartridge service life.

The TR-830N battery is intrinsically safe only when correctly attached to the TR-800N blower. Change batteries and use the TR-642N charger only in a location known to be non-hazardous. The charger is not intrinsically safe. Never substitute or modify system components.

Frequently asked questions

Does the TR-800-PSK include everything needed to begin use?

The kit includes the core blower, battery, charger, helmet, breathing tube, cartridge, belt, covers, airflow indicator, attachment tool, and cleaning/storage components. A qualified program administrator must still confirm that the configuration, cartridge, assigned protection factor, change-out schedule, training, and workplace procedures are suitable for the specific exposure.

How long does the TR-830N battery run?

3M lists an approximate runtime of 4 to 8 hours for a new battery and filter at about 20°C to 21°C. Actual runtime varies with headgear, filter or cartridge, selected airflow, filter loading, battery condition, temperature, and work environment.

Can the battery be charged in a hazardous location?

No. The charger is not intrinsically safe. The TR-830N battery must be changed and charged only in an area known to be non-hazardous, using the approved 3M charger and following the battery and charger instructions.

Does the alarm indicate when the gas and vapour cartridge is exhausted?

No. The filter-loading indicator relates only to particulate loading. Gas and vapour cartridge service life must be managed through a documented change-out schedule based on the contaminant, concentration, humidity, temperature, work rate, and other workplace conditions.

Recently viewed